// no direct access defined('_JEXEC') or die('Restricted access'); // including base setup file include_once(JPATH_ROOT . "/templates/" . $this->template . '/lib/php/gk_setup.php'); // including menu generator file include_once(JPATH_ROOT . "/templates/" . $this->template . '/lib/php/menu.php'); ?> KSB Movitec
KSB Movitec
Written by Administrator    Monday, 11 October 2010 12:00    PDF Print E-mail
Movitec Type Series Booklet
1798.5/2-10

Fields of Application

Movitec VE are employed for general water supply, sprinkling, irrigation
and pressure boosting duties, for warm water and cooling
water recirculation. They are installed in domestic water supply systems,
washing plants, water treatment and fire-fighting systems.
Movitec V(S) and LHS are employed for general water supply,
sprinkling, irrigation and pressure boosting duties, for warm water,
hot water and cooling water recirculation, and condensate transport.
They are installed in boiler feed circuits, domestic water supply
systems, washing plants, water treatment and filter systems.
They are used for degreaser baths/alkaline cleaning baths, alkalines
and oils/emulsions, as well as for fire-fighting, reverse osmosis
and surface treatment applications.
Designation

Type-series
Movitec V
Movitec VE (close-coupled design)
Material variant
Flange variant
Pump size
Number of stages
Movitec LHS 6 - 10
Type-series

Pump size
Number of stages
Material variants: blank or S, see page 3
Flange variants/connections: blank = oval flange
F = round flange
V = Victaulic coupling
E = thread (male)
Design

Multi-stage, vertical (horizontal installation see page 5) high-pressure
centrifugal pumps, with suction and discharge nozzles of
identical nominal diameters arranged opposite to each other (inline
design).
Operating Data

Movitec VE
Capacities Q up to 11.9 m3/h, (3.3 l/s)
Heads H up to 70 m
Operating pressures pd up to 10 bar 1)
Operating temperatures t -15 C to +60 C
Movitec V(S)
Capacities Q up to 75 m3/h, (21 l/s)
Heads H up to 249 m
Operating pressures pd up to 25 bar 1)
Operating temperatures t -15 C to +120 C
Movitec LHS
Capacities Q up to 8.6 m3/h, (2.4 l/s)
Heads H up to 401 m
Operating pressures pd up to 40 bar 1)
Operating temperatures t -15 C to +120 C
1) The sum of inlet pressure and head at zero flow point must not exceed
the value stated.
Materials

Standard variants:
VE, V: All hydraulic components are made of stainless steel
AISI 304
VS, LHS: All hydraulic components are made of stainless steel
AISI 316
Conformity Marks

CE
ACS (Movitec VE / V)
ATEX group II, cat. 2 and 3 on request
Bearings

All V, VS and LHS pumps are supplied with tungsten carbide plain
bearing at the hydraulic rotor.
Movitec VE is supplied without bearing at the hydraulic rotor.
Shaft Seal

Single-acting, uncooled mechanical seal in accordance with
EN 12756.
Drive

Electric motor, 50 Hz, air-cooled, 2- and 4-pole, standard KSB
motor with main dimensions to IEC. Other motor makes subject to
prior consultation with KSB.
Movitec V, VS, LHS with PTC resistors for 3 kW and above.
Variants: single-phase a.c. motor, frequency-controlled drives,
60 Hz (see Type Series Booklet 1798.56-10).